The EABL table in SAP ERP or S/4HANA stores MR Document data. There are total 82 fields in EABL table. The MR Document table is available in all major SAP S/4HANA versions, is implemented as a Column Store table within the SAP HANA database. Additionally we provide an overview of the structure and fields of EABL table. It is in IS-U: Meter Reading Order Creation (EE16) ABAP package and is part of the Meter Reading (IS-U-DM-MR) module.
SAP EABL Table Fields
Following is the list of fields that are available in SAP EABL table. The primary key fields of the table are MANDT (Client), ABLBELNR (Internal ID for meter reading document).
| Field | Description | Data Element | Check Table | Data Type |
|---|---|---|---|---|
| MANDT | Client | MANDT | T000 | CLNT (3) |
| ABLBELNR | Internal ID for meter reading document | ABLBELNR | CHAR (20) | |
| GERNR | Device | GERAET | CHAR (18) | |
| EQUNR | Equipment Number | EQUNR | EQUI | CHAR (18) |
| ZWNUMMER | Register | E_ZWNUMMER | NUMC (3) | |
| ADAT | Meter reading date relevant to billing | ADAT | DATS (8) | |
| ATIM | Meter reading time (relevant to billing) | ATIM | CHAR (4) | |
| V_ZWSTAND | Places Before Decimal Point in Meter Reading | V_ZWSTAND | DEC (17) | |
| N_ZWSTAND | Places After Decimal Point in the Meter Reading | N_ZWSTAND | DEC (14) | |
| V_ZWSTNDAB | Predecimal Places in Billed Meter Reading | V_ZWSTNDAB | DEC (17) | |
| N_ZWSTNDAB | Decimal Places in the Billed Meter Reading | N_ZWSTNDAB | DEC (14) | |
| MASSREAD | Unit of measurement for meter reading | E_MASSREAD | T006 | UNIT (3) |
| MASSBILL | Unit of measurement for billing | E_MASSBILL | T006 | UNIT (3) |
| STANZVOR | Number of predecimal places for register | STANZVORE | NUMC (2) | |
| STANZNAC | Number of decimal places for register | STANZNACE | NUMC (2) | |
| SCHAEVER | Estimation procedure | SCHAEVER | CHAR (2) | |
| SCHAEGR | Estimation reason | SCHAEGR | TE567 | CHAR (2) |
| AKTIV | Meter reading active | E_AKTIV | CHAR (1) | |
| ADATSOLL | Scheduled meter reading date | ADATSOLL | DATS (8) | |
| ADATMAX | Date of maximum meter reading | ADATMAX | DATS (8) | |
| ATIMMAX | Time of maximum meter reading | ATIMMAX | CHAR (4) | |
| ADATTATS | Actual meter reading date | ADATTATS | DATS (8) | |
| ATIMTATS | Actual meter reading time | ATIMTATS | CHAR (4) | |
| ADATERZ | Meter reading date of implausible meter reading result | ADATERZ | DATS (8) | |
| ATIMERZ | Meter reading time of implausible meter reading result | ATIMERZ | CHAR (4) | |
| ADATPROG | Meter reading date from which forecast is made | ADATPROG | DATS (8) | |
| ATIMPROG | Meter reading time from which consumption is determined | ATIMPROG | CHAR (4) | |
| ZUORDDAT | Meter reading allocation date | E_ZUORDDAT | DATS (8) | |
| THGDATUM | Gas allocation date | THGDATUM | DATS (8) | |
| PRUEFZAHL | Check number | PRUEFZAHL | NUMC (2) | |
| BAPERTYP | Base period category | BAPERTYP | CHAR (1) | |
| ABLSTAT | Meter Reading Status | ABLSTAT | CHAR (1) | |
| PRUEFPKT | Independent validation | PRUEFPKT | TE218 | CHAR (2) |
| POPCODE | Dependent validation | POPCODE | TE625 | CHAR (2) |
| PRUEFTYP | Validation category for meter readings | PRUEFTYP | CHAR (1) | |
| ABLHINW | Note from meter reader | ABLHINW | TE259 | CHAR (4) |
| STABLHW | Control of follow-up action for MR result with MR note | STABLHW | CHAR (2) | |
| KONTRVRF | Indicator: dummy record from automatic control procedure | KONTRVRF | CHAR (1) | |
| ABLESART | Scheduled meter reading category | GEPLABL | TE614 | CHAR (2) |
| ABLESER | Meter reader number | ABLESER | TE115 | CHAR (3) |
| NACHERF | Meter reading result inserted or modified | NACHERF | CHAR (1) | |
| MDENR | Number for mobile data entry (MDE) | MDENR | NUMC (3) | |
| E_ZEITVBL | Multiple meter reading order creation | E_ZEITVBL | CHAR (1) | |
| E_ZVLZUORD | Multiple allocation | E_ZVLZUORD | NUMC (3) | |
| STEUERGRP | Control group for multiple meter reading order creation | STEUERGRP | TE629 | CHAR (4) |
| ARBAUF | Control Meter Reading Order ID Printed | ARBAUF | CHAR (1) | |
| KSTATUS | Status for automatic monitoring of meter reading order | E_KSTATUS | CHAR (1) | |
| ERDAT | Date on which the record was created | ERDAT | DATS (8) | |
| ERNAM | Name of Person who Created the Object | ERNAM | CHAR (12) | |
| AEDAT | Date of Last Change | AEDAT | DATS (8) | |
| AENAM | Name of person who changed object | AENAM | CHAR (12) | |
| ENTRYNUMB | Entry number for fast entry | ENTRYNUMB | NUMC (8) | |
| ACTOR | Concatinated Identification (Type and ID) of Org. Objects | HROBJEC_14 | CHAR (14) | |
| ISTABLART | Meter reading type | ISTABLART | TE436 | CHAR (2) |
| ABLESTYP | Meter reading category | ABLESTYP | TE614 | CHAR (2) |
| E_ZVBL_BEZDAT | Scheduled meter reading date for base meter reading | E_ZVBL_BEZDAT | DATS (8) | |
| SM_AUFNR | Service order or notification | PM_SVCNR | CHAR (12) | |
| DOC_TYPE | Document category for plant maintenance and customer service | KZ_SM_DOC_TYPE | CHAR (1) | |
| ADATREAL | [JBP] Real Meter Reading Date | ADATREAL | DATS (8) | |
| ATIMREAL | [JBP] Real Meter Reading Time | ATIMREAL | CHAR (4) | |
| S_ISTABLART | [JBP] Meter Reading Type for Original Meter Reading | S_ISTABLART | CHAR (2) | |
| S_AKTIV | [JBP] Orig. Meter Reading: Meter Reading Active | S_AKTIV | CHAR (1) | |
| S_ABLSTAT | [JBP] Original Meter Reading Status | S_ABLSTAT | CHAR (1) | |
| S_V_ZWSTAND | [JBP] Orig. MR: Decimal Places Before Meter reading | S_V_ZWSTAND | DEC (17) | |
| S_N_ZWSTAND | [JBP] Decimal Places of Meter Readings for Original MR | S_N_ZWSTAND | DEC (14) | |
| S_V_ZWSTNDAB | [JBP] Predecimal Places of Billed MR for Original MR | S_V_ZWSTNDAB | DEC (17) | |
| S_N_ZWSTNDAB | [JBP] Decimal Places of Billed Orginal Meter Reading | S_N_ZWSTNDAB | DEC (14) | |
| REMOVED | [JBP] Status Indicator: MR Result Suppressed | REMOVED | CHAR (1) | |
| BP | Selection of Billing Period: Standard or JBP | BP | CHAR (1) | |
| REM_ABLBELNR | [JBP] Suppressed MR Document Number | REM_ABLBELNR | CHAR (20) | |
| REM_ABLESER | Meter Reader Number of Suppressed Meter Reading | R_ABLESER | * | CHAR (3) |
| S_ADATSOLL | Scheduled meter reading date | ADATSOLL | DATS (8) | |
| S_ZVBL_BEZDAT | Scheduled meter reading date for base meter reading | E_ZVBL_BEZDAT | DATS (8) | |
| AMS | Advanced Metering System | E_AMI_AMS | TEAMI_AMS | CHAR (4) |
| TRANSSTAT | Transfer Status Code | E_AMI_MR_TRANSSTAT | ISU_F4_AMITRSTAT | CHAR (5) |
| TRANSTSTAMP | UTC Time Stamp in Long Form (YYYYMMDDhhmmssmmmuuun) | TIMESTAMPL | DEC (21) | |
| SOURCESYST | Source System From Which Data is Requested | E_AMI_SOURCESYST | NUMC (1) | |
| QNT | Quantity Determined from Meter Reading in Internal Format | E_QD_QNT | DEC (31) | |
| QDSTAT | Status of Quantity Determination | E_QD_STAT | CHAR (2) | |
| QDPROC | Qty Determination Procedure During Meter Reading / Billing | E_QD_PROC_MR | NUMC (2) | |
| PREV_MRDOC | Internal ID of Previous Meter Reading Result Document | E_QD_PREV_MRDOC | CHAR (20) | |
| COLOGRP | Colocation group for Meter Reading | E_COLOGRP_MR | CHAR (12) |